Avila Solar Drafting commissions PV systems up to 1 MW. Commissioning is the step between installation and operation: we test the system against its design, confirm it runs safely and document the results. Testing covers insulation resistance, I-V curve tracing up to 1500 Vdc, continuity, inverter checks and thermal imaging. Request a quote with your system size and site address.
An installed system can look finished and still carry a reversed string, a damaged conductor or a loose termination. Commissioning finds those problems before the system goes into service. Pair it with a solar production report and you have both the expected output and the measured string data.
The commissioning record becomes the baseline that every later inspection or maintenance visit is measured against. Avila Solar maintains calibrated test equipment and reviews its procedures as module and inverter technology changes.
Megger testing confirms conductor insulation integrity, so ground faults are caught before the system goes into service.
A visual checklist, an as-built drawing review, bolt torque checks and digital documentation of the major components.
String I-V curves traced up to 1500 Vdc to find shunt losses, module mismatch and degradation.
Grounding continuity confirmed across modules, inverters, transformers and ground rods.
Inverter readiness verified against the manufacturer's guidelines and current best practice.
Infrared imaging finds manufacturing defects, resistive terminations and overheating components.
Avila Solar's standard commissioning covers PV systems up to 1 MW. Depending on the project, Avila Solar commissions as the lead team or alongside a partner commissioning firm.
If Avila Solar also drafted the system through our commercial solar PV design service, the plan set and the commissioning record come from the same office. If you would rather run string tests with your own crew, you can rent our I-V curve tracer.
The commissioning quote form asks for the system size, the site address and state, and lets you upload system specs or plans. The more complete the plan set you send, the faster Avila Solar can scope the visit.
If labels or grounding details are still open with the inspector, our guides to solar labels and placards and solar grounding and bonding cover what NEC 2023 expects. The international standard IEC 62446-1 sets out the documentation, commissioning tests and inspection criteria for grid-connected PV systems.
Avila Solar's standard commissioning covers PV systems up to 1 MW. For a larger system, call 971-410-0655 before you request a quote so Avila Solar can tell you what it can support.
Avila Solar traces I-V curves up to 1500 Vdc, which covers string voltages on both 1000 V and 1500 V system designs.
No. Commissioning tests and documents how a PV system performs; the authority having jurisdiction and the utility make their own decisions. A commissioning record gives you evidence of how the system tested when it went into service.
Yes. Avila Solar rents the HT Instruments I-V600 curve tracer, rated for PV strings up to 1500 V and 40 A, by the day, week or month.
Use Avila Solar's commissioning quote form to send the system size, site address, state and any specs or plans, or call 971-410-0655.
Send the system size and site address through the commissioning quote form, or call 971-410-0655.